Common electrical data, filling pressure and temperature |
Rated insulation level | Rated voltage Ur | kV | 12 | 24 | 36 | 40.5 | ||||
Rated short-duration power-frequency -phase-to-earth, open contact gap - across the isolating distance |
kV kV |
28 1) 32 1) |
50 2) 60 2) |
70 80 |
85 3) 90 3) |
||||||
-Rated lightning impulse withstand voltage Up : -phase-to-earth, open contact gap - across the isolating distance |
kV kV |
75 85 |
125 145 |
170 195 |
185 4) 220 4) |
||||||
Rated frequency fr | Hz | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | ||||||
Rated normal current Ir | for the busbar 9) | A A |
1250 2000 |
1250 2000 |
1250 2000 |
1250 2000 |
|||||
A | 2500 | 2500 | 2500 | 2500 | |||||||
A | 3150 | 3150 | 3150 | 3150 | |||||||
A | 4000 | 4000 | 4000 | 4000 | |||||||
A | 5000 | 5000 | 5000 | 5000 | |||||||
Rated filling level pre | for the busbar | 70/120 kPa at 20 °C | |||||||||
Minimum functional level pme | 50/100 kPa at 20 °C | ||||||||||
Ambient air temperature | - 5 °C to + 55 °C | ||||||||||
Data of the switchgear panels | |||||||||||
Circuit-breaker
panel, discon
nector panel 6)
|
Rated normal current Ir 9) A A A A A |
1250 1600 2000 2300 2500 |
1250 1600 2000 2300 2500 |
1250 1600 2000 2300 2500 |
1250 1600 2000 2300 2500 |
||||||
Rated short-time withstand current Ik tk = 3 s up to kA | 40 | 40 | 40 | 40 | |||||||
Rated peak withstand current Ip 5) up to kA | 100/104 | 100/104 | 100/104 | 100/104 | |||||||
Rated short-circuit making current Ima 5) | up to | kA | 100/104 | 100/104 | 100/104 | 100/104 | |||||
Rated short-circuit breaking current Isc | up to | kA | 40 | 40 | 40 | 40 | |||||
Electrical endurance of vacuum circuit-breakers |
at rated normal current at rated short-circuit breaking current |
10,000 operating cycles | |||||||||
50 breaking operations | |||||||||||
Rated filling level pre for feeders | 70/120 kPa at 20 °C | ||||||||||
Minimum functional level pme | 50/100 kPa at 20 °C | ||||||||||
Bus section-alizer, bus
coupler 7)
|
Rated normal current Ir 9) A A A A |
1250 2000 2300 2500 |
1250 2000 2300 2500 |
1250 2000 2300 2500 |
1250 2000 2300 2500 |
||||||
Rated short-time withstand current Ik tk = 3 s up to kA | 40 | 40 | 40 | 40 | |||||||
Rated peak withstand current Ip 5) up to kA | 100/104 | 100/104 | 100/104 | 100/104 | |||||||
Rated short-circuit making current Ima 5) up to kA | 100/104 | 100/104 | 100/104 | 100/104 | |||||||
Rated short-circuit breaking current Isc up to kA | 40 | 40 | 40 | 40 | |||||||
Electrical endurance of vacuum circuit-breakers |
10,000 operating cycles | ||||||||||
50 breaking operations | |||||||||||
Rated filling level pre for feeders | 70/120 kPa at 20 °C | ||||||||||
Minimum functional level | pme | 50/100 kPa at 20 °C | |||||||||
Cable connec- tion panel, metering panel |
Rated normal current Ir 8) 9) A | 1250 | 1250 | 1250 | 1250 | ||||||
A | 1600 | 1600 | 1600 | 1600 | |||||||
A | 2000 | 2000 | 2000 | 2000 | |||||||
A | 2500 | 2500 | 2500 | 2500 | |||||||
Rated short-time withstand current Ik tk = 3 s up to kA | 40 | 40 | 40 | 40 | |||||||
Rated peak withstand current Ip 5) up to kA | 100/104 | 100/104 | 100/104 | 100/104 | |||||||
Rated filling level pre for feeders | 70/120 kPa at 20 °C | ||||||||||
Minimum functional level | pme | 50/100 kPa at 20 °C |