Xgn-12 Fully Insulated and Fully Enclosed Gas Ring Main Unit

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Steel Plate
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Fast Delivery
The supplier can deliver the goods within 15 days
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (14)
  • Xgn-12 Fully Insulated and Fully Enclosed Gas Ring Main Unit
  • Xgn-12 Fully Insulated and Fully Enclosed Gas Ring Main Unit
  • Xgn-12 Fully Insulated and Fully Enclosed Gas Ring Main Unit
Find Similar Products
  • Overview
  • Scope of application
  • Conditions of normal use
  • Detailed Photos
  • Specification
Overview

Basic Info.

Model NO.
XGN74-12
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Rated Voltage
12kv
Rated Current
630/1250A
Rated Current of The Fuse
125A
Rated Frequency
50Hz
Rated Peak Withstand Current
50ka/S
Ingress Protection
Ipx2
Transport Package
Carton for Export
Specification
950× 500× 1600mm
Trademark
CHINT
Origin
China

Product Description

   
Scope of application

     XGN15-12 box-type fixed AC metal-enclosed switchgear, also known as indoor AC high-voltage sulfur hexafluoride ring network switchgear (hereinafter referred to as "switchgear"), is a new generation of sulfur hexafluoride load switch as the main switch and the whole cabinet is air-insulated, suitable for distribution automation, both compact and scalable metal-enclosed switchgear.
  The ring main unit has the characteristics of simple structure, flexible operation and reliable interlocking. For a variety of different applications, different user requirements
All can provide satisfactory technical solutions.
The use of sensing technology and the latest protective relays is combined with advanced technical performance and lightweight and flexible assembly solutions. It can meet the requirements of market changes.

  The switchgear is suitable for the rated frequency of 50Hz, the rated voltage of 12/24kV power grid system, the system configuration scheme is extensive, comprehensive, is the urban power grid transformation and construction of the new generation of medium voltage switchgear. This product conforms to IEC62271-200, GB3906, GB3804, GB16926, GB/T11022 and other standards.
Conditions of normal use
·Ambient air temperature: - 15°C~ 40°C;
·Altitude: no more than 1000m;
·Relative humidity: the daily average relative humidity is not more than 95%, and the daily average water vapor
pressure is not more than 2.2kPa;

The monthly average relative humidity is not more than 90%, and the daily average water vapor
pressure is not more than 1.8kPa;

·Seismic intensity: no more than 8 degrees;
·Non-corrosive, violent vibration, impact, explosion hazard places;
Detailed Photos

Xgn-12 Fully Insulated and Fully Enclosed Gas Ring Main UnitXgn-12 Fully Insulated and Fully Enclosed Gas Ring Main UnitXgn-12 Fully Insulated and Fully Enclosed Gas Ring Main UnitXgn-12 Fully Insulated and Fully Enclosed Gas Ring Main UnitXgn-12 Fully Insulated and Fully Enclosed Gas Ring Main UnitXgn-12 Fully Insulated and Fully Enclosed Gas Ring Main Unit

Specification
 
Type C Model F Model       V Model              CB Model
Loadswitch   VCB disconector / earth switch VCB disconector / earth switch
Rated voltage kV 12 12 12 12 12 12
Rated frequency Hz 50 50 50 50 50 50
power frequency withstand voltage( phase to phase /to the ground ) kV 42/48 42/48 42/48 42/48 42/48 42/48
Lightning impluse withstand voltage kV 75/85 75/85 75/85 75/85 75/85 75/85
Rated current A 630   630   1250/630  
Rated closed-loop interrupting current A 630          
Rated cable charging breaking current A 135/135          
Rated short-circuit closing current ( peak ) A 50 80        
Rated peak withstand current kA 50          
Rated short-time withstand current kA/3s 20          
Rated short-circuit opening current kA   31.5 20   25  
Rated transfer current A   1750        
Equipped with fuse maximum current A - 125        
Loop resistance -n ≤300 ≤600        
Machanical life time 5000 3000 5000 2000 5000 500