Customization: | Available |
---|---|
Certification: | VDE |
Shell Material: | Steel Plate |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The PIX series switchgear has a comprehensive range of solutions to meet the needs of customers
For the same requirements, the configuration of different solutions will be different, and the overall score will be different
For the following components:
• Cabinets
• Protection, monitoring and control systems
• Parts can be removed from the room
Depending on the function of the electrical equipment, there are four compartments with different functions:
Bus room, trolley room, cable room and low-voltage room, between compartmentsIP2X degree of protection is possible
Pressures are provided above the busbar, trolley and cable rooms release device. When an internal fault arc occurs, it is accompanied by arcing the appearance of the switchgear internal air pressure rises, and the top is installed,The pressure release metal plate will be automatically opened, releasing the pressure and discharge
Vent gas to ensure operator and switchgear safety
Rated voltage and frequency | |||||
Rated voltage - Ur kV 7.2 12 24 | |||||
Rated frequency - fr Hz | 50/60 | 50/60 | 50 | ||
Rated insulated level | |||||
Rated short time power withstand voltage( 1min )- Ud kV | 20(1)/30 | 28(1)/42 | 50(1)/65 | ||
Rated lightning impulse withstand voltage (peak) - Up kV | 60 | 75 | 125 | ||
Rated current and rated short-time withstand current | |||||
Functional unit with circuit breaker | |||||
Rated current - Ir A | 630 | 630 | 630 | ||
1250 | 1250 | 1250 | |||
1600 | 1600 | 1600 | |||
2000 | 2000 | 2000 | |||
2500 | 2500 | 2500 | |||
3150 | 3150 | 3150(2) | |||
4000(2) | 4000(2) | 4000(2) | |||
5000(2) | 5000(2) | ||||
6300(3) | |||||
Rated short-time withstand current( 4s )- Ik kA | ...50 | ...50/63(3) | ...40 | ||
Rated peak withstand current - Ip kA | …125/150 | …125/150/160(3) | …100 | ||
The maximum rated current of the main bus - Ir max. busbar | A | 5000 | 5000/6300(3) | 4000 | |
The auxiliary circuit and the control circuit are rated at the power frequency withstand voltage - Ud aux. kV |
2 | 2 | 2 | ||
Functional unit with contactor-fuse combination | |||||
Rated current - Ir A | 250 | 160 | |||
Rated short-time withstand current( 4s )- Ik kA | 50 | 50 | |||
Internal arc rating | |||||
Maximum arc fault current - Isc max. kA | 50 | 50 | 40 | ||
Arc fault duration - t s | 1 | 1 | 1 | ||
grade | AFLR | AFLR | AFLR | ||
Ingress protection | |||||
Cabinet shell | IP4X(4) | IP4X(4) | IP4X(4) | ||
When the door to the carriage compartment is opened | IP2X | IP2X | IP2X |