M-PACT low pressure air circuit breakers with current ratings ranging from 400 to 4000A.
Designed to meet the user's requirements for rapid detection and safe isolation of faults, the new generation of low-pressure air circuit breakers can effectively protect the low-voltage power distribution system from damage and minimize maintenance costs and power outage time.
The product is based on the development of other full range of low-voltage electrical products. It has a high degree of coordination of power distribution protection, consistency of appearance and installation dimensions.
Rated Current Setting Range (40°C) | 400 | 800 | 1000 | 1250 | ||||||||||||||||||||||||||||||||
Lifetime (number of opening and closing operations) | ||||||||||||||||||||||||||||||||||||
Mechanical life (with maintenance) | 40000 | 40000 | 25000 | 40000 | 25000 | 40000 | 25000 | |||||||||||||||||||||||||||||
Mechanical life (no maintenance) | 25000 | 25000 | 15000 | 25000 | 15000 | 25000 | 15000 | |||||||||||||||||||||||||||||
Electrical life (at rated current) | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | |||||||||||||||||||||||||||||
Rated operating voltage (50/60 Hz) | Ue | V | 690 | 690 | 690 | 690 | ||||||||||||||||||||||||||||||
Rated absolute green voltage (50/60 Hz) | Ui | V | 1000 | 1000 | 1000 | 1000 | ||||||||||||||||||||||||||||||
Rated impact pressure | Uimp | V | 12000 | 12000 | 12000 | 12000 | 12000 | 12000 | 12000 | |||||||||||||||||||||||||||
Number of poles | 3 & 4 | 3 & 4 | 3 & 4 | 3 & 4 | ||||||||||||||||||||||||||||||||
Fourth pole capacity | 100% | 100% | 100% | 100% | ||||||||||||||||||||||||||||||||
Break code | A | D | A | D | H1 | H2 | A | D | H1 | H2 | A | D | H1 | H2 | ||||||||||||||||||||||
Frame level | 1 | 1 | 1 | 1 | 2 | 2 | 1 | 1 | 2 | 2 | 1 | 1 | 2 | 2 | ||||||||||||||||||||||
Rated limit short-circuit breaking capacity | Icu | kA (rms | ) 220V | 50 | 70 | 50 | 70 | 80 | 80 | 50 | 70 | 80 | 80 | 50 | 70 | 80 | 80 | |||||||||||||||||||
Breaking capacity | 415V | 50 | 70 | 50 | 70 | 80 | 80 | 50 | 70 | 80 | 80 | 50 | 70 | 80 | 80 | |||||||||||||||||||||
500V | 50 | 50 | 80 | 50 | 80 | 50 | 80 | |||||||||||||||||||||||||||||
600V | 50 | 50 | 65 | 50 | 65 | 50 | 65 | |||||||||||||||||||||||||||||
690V | 50 | 50 | 65 | 50 | 65 | 50 | 65 | |||||||||||||||||||||||||||||
Rated operating short-circuit breaking capacity | Ics | kA (rms | ) 220V | 50 | 65 | 50 | 65 | 80 | 80 | 50 | 65 | 80 | 80 | 50 | 65 | 80 | 80 | |||||||||||||||||||
Breaking capacity | 415V | 50 | 65 | 50 | 65 | 80 | 80 | 50 | 65 | 80 | 80 | 50 | 65 | 80 | 80 | |||||||||||||||||||||
500V | 50 | 50 | 80 | 50 | 80 | 50 | 80 | |||||||||||||||||||||||||||||
600V | 50 | 50 | 65 | 50 | 65 | 50 | 65 | |||||||||||||||||||||||||||||
690V | 50 | 50 | 65 | 50 | 65 | 50 | 65 | |||||||||||||||||||||||||||||
Rated short-time withstand current | ||||||||||||||||||||||||||||||||||||
1 second | Icw 415/690VA | ckA (rms) | 50 | 65/50 | 50 | 65/50 | 65 | 80 | 50 | 65/50 | 65 | 80 | 50 | 65/50 | 65 | 80 | ||||||||||||||||||||
3 seconds | Icw | kA (rms) | 50 | 50 | 50 | 50 | ||||||||||||||||||||||||||||||
Rated short-time turn-on capability | Icm | kA (peak | ) 415V | 105 | 143 | 105 | 143 | 176 | 176 | 105 | 143 | 176 | 176 | 105 | 143 | 176 | 176 | |||||||||||||||||||
500V | 143 | 143 | 176 | 143 | 176 | 143 | 176 | |||||||||||||||||||||||||||||
600V | 105 | 105 | 143 | 105 | 143 | 105 | 143 | |||||||||||||||||||||||||||||
690V | 84 | 84 | 105 | 84 | 105 | 84 | 105 | |||||||||||||||||||||||||||||
Power Consumption (Stationary) | W | 15 | 10 | 63 | 43 | 23 | 20 | 106 | 68 | 36 | 32 | 175 | 105 | 60 | 53 | |||||||||||||||||||||
Power Consumption (Extraction) | W | 30 | 21 | 127 | 86 | 49 | 43 | 211 | 135 | 77 | 68 | 351 | 211 | 128 | 113 |